Boots CS-1000 Bedienungsanleitung Seite 300

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 400
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 299
Notes
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
Once the D-Channel card is enables we
can try to establish the link.
In LD 60 we can use the ENLL <Loop
Number> to bring the LOOP into
service. This needs to be done on both
systems i.e. both ends of the link before
the service will correctly establish.
If necessary the LOOP can be disabled
using the DISL <Loop Number>
command and the counters listed LCNT
and reset RCNT before re-enabling the
LOOP to clear any issues.
CS 1000 Rel 7.5 08092801
Page 300
Copyright Amlex Associates Ltd
Seitenansicht 299
1 2 ... 295 296 297 298 299 300 301 302 303 304 305 ... 399 400

Kommentare zu diesen Handbüchern

Keine Kommentare